USB4000
Miniature Fiber Optic Spectrometer
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Item | Description | Price |
| USB4000 | USB4000 User-configured Spectrometer. User to specify a USB4000 Detector (see 4 detector options) and USB4000 Spectrometer Optical Bench Options * | $2540 |
| SpectraSuite | SpectraSuite Spectroscopy Operating Software | $199 |
* Pre-configured, off-the-shelf USB4000 Spectrometers (such as the USB4000-UV-VIS, USB4000-VIS-NIR and USB4000-FL) have the detector and other bench components built-in.
|
Physical |
|
| Dimensions: | 89.1 mm x 63.3 mm x 34.4 mm |
| Weight: | 190 grams |
| Detector Specifications | |
|
Detector: |
Toshiba TCD1304AP Linear CCD array |
| Detector range: | 200-1100 nm |
|
Pixels: |
3648 pixels |
|
Pixel size: |
8 μm x 200 μm |
|
Pixel well depth: |
100,000 electrons |
| Signal-to-noise ratio: | 300:1 (at full signal) |
| A/D resolution: | 16 bit |
| Dark noise: | 50 RMS counts |
| Corrected linearity: | >99.8% |
| Sensitivity: | 130 photons/count at 400 nm; 60 photons/count at 600 nm |
| Optical Bench | |
| Design: | f/4, Asymmetrical crossed Czerny-Turner |
| Focal length: | 42 mm input; 68 mm output |
| Entrance aperture: | 5, 10, 25, 50, 100 or 200 µm wide slits or fiber (no slit) |
| Grating options: | 14 different grating options, UV through Shortwave NIR |
| HC-1 grating option: | No |
| Detector collection lens option: | Yes, L4 |
| DET4 filter options: | DET4-200-850; DET4-350-1000 |
| Other bench filter options: | Longpass OF-1 filters |
| Collimating and focusing mirrors: | Standard or SAG+UPG |
| UV enhanced window: | Yes, UV4 |
| Fiber optic connector: | SMA 905 to 0.22 numerical aperture single-strand optical fiber |
| Spectroscopic | |
| Wavelength range: | Grating dependent |
| Optical resolution: | ~0.3-10.0 nm FWHM (grating dependent) |
| Signal-to-noise ratio: | 300:1 (at full signal) |
| A/D resolution: | 16 bit |
| Dark noise: | 50 RMS counts |
| Integration time: | 3.8 ms - 10 seconds |
| Dynamic range: | 2 x 108 (system), 1300:1 for a single acquisition |
| Stray light: | <0.05% at 600 nm; 0.10% at 435 nm |
| Electronics | |
| Power consumption: | 250 mA @ 5 VDC |
| Data transfer speed: | Full spectrum to memory every 4 ms with USB 2.0 port |
| Inputs/Outputs: | Yes, 8 onboard digital user-programmable GPIOs |
| Analog channels: | No |
| Auto nulling: | Yes |
| Breakout box compatible: | Yes, with the USB-ADP-BB adapter |
| Trigger modes: | 4 modes |
| Strobe functions: | Yes |
| Connector: | 22-pin connector |
| Computer | |
| Operating systems: | Windows 98/Me/2000/XP, Mac OS X and Linux with USB port; Any 32-bit Windows OS with serial port |
| Computer interfaces: | USB 2.0 @ 480 Mbps (USB1.1 compatible); RS-232 (2-wire) @ 115.2 K baud |
| Peripheral interfaces: | SPI (3-wire); I2C inter-integrated circuit |
Serial port operation tips: When using the serial port, the USB4000 requires a single 5-volt power supply (not included). Also, SpectraSuite Spectroscopy Software does not support spectrometer operation via the serial port. However, using the included Serial Port Command Set, you can write your own software that makes serial port operation possible.
![]()
Contact
an
Ocean Optics
Applications Scientist
Convenient Wavelength Calibration! Click here for Details
| . | |||||||||
|
|
|||||||||
| HOME | PRODUCTS | SERVICES | TECHNICAL | APPLICATIONS | CORPORATE | DISTRIBUTORS | CATALOG | NEWSLETTER | CONTACT |
![]() ![]() ![]() . Copyright 1989 - 2010 Ocean Optics, Inc. All rights reserved. Terms of Use and Privacy Statement +1 727.733.2447 • +1 Fax 727.733.3962 • |
|||||||||